Smart DIPSS for Dynamic Stability Enchancement on Multi-Machine Power System

Herlambang Setiadi, Fakhruddin Arrazi, Muhammad Abdillah, Awan Uji Krismanto

Abstract


Disruption of the electric power system always results in instability. These disturbances can be in the form of network breaks (transients) or load changes (dynamic). Changes in load that occur suddenly and periodically cannot be responded well by the generator so that it can affect the dynamic stability of the system. This causes the occurrence of frequency oscillations in the generator. A poor response can cause frequency oscillations for a long period. This will result in a reduction in the available power transfer power. In a multi-machine power system, all the machines work in synchrony, so the generator must operate at the same frequency. Therefore, disturbances that arise will have a direct impact on changes in electrical power. In addition, changes in electrical power will have an impact on mechanical power. The difference in response speed between a fast electrical power response and a slower mechanical power response will result in instability. As a result of these differences, the system oscillates. The addition of the excitation circuit gain is less able to stabilize the system. To solve the problem, additional signal changes are required. The additional signal is generated by the Dual Input Power System Stabilizer (DIPSS) setting using the Ant Colony Optimization (ACO) method.

Disruption of the electric power system always results in instability. These disturbances can be in the form of network breaks (transients) or load changes (dynamic). Changes in load that occur suddenly and periodically cannot be responded well by the generator so that it can affect the dynamic stability of the system. This causes the occurrence of frequency oscillations in the generator. A poor response can cause frequency oscillations for a long period. This will result in a reduction in the available power transfer power. In a multi-machine power system, all the machines work in synchrony, so the generator must operate at the same frequency. Therefore, disturbances that arise will have a direct impact on changes in electrical power. In addition, changes in electrical power will have an impact on mechanical power. The difference in response speed between a fast electrical power response and a slower mechanical power response will result in instability. As a result of these differences, the system oscillates. The addition of the excitation circuit gain is less able to stabilize the system. To solve the problem, additional signal changes are required. The additional signal is generated by the Dual Input Power System Stabilizer (DIPSS) setting using the Ant Colony Optimization (ACO) method.


Keywords


ACO; Clean Energy Technology; DIPSS; Stability; Multimachine

Full Text: PDF

Refbacks

  • There are currently no refbacks.


 

Indonesian Journal of Electrical Engineering and Informatics (IJEEI)
ISSN 2089-3272

Creative Commons Licence

This work is licensed under a Creative Commons Attribution 4.0 International License.

web analytics
View IJEEI Stats

Error. Page cannot be displayed. Please contact your service provider for more details. (3)