Partial Discharge Source Identification Using Pulse Height Distribution for Diagnosis in High Voltage Rotating Machines
Abstract
References
REFERENCES
F. H. Kreuger, Partial Discharge Detection in High Voltage Equipment, Temple Press, 1989.
S. Mohanty, S Ghosh, “Modeling of breakdown voltage of White Minilex Paper in the presence of voids under ac and dc conditions using fuzzy logic techniquesâ€, International Journal of Electrical Power & Energy Systems, Vol. 32, Issue. 5, pp. 518-523, 2010.
Shoji Hirabayashi, Yoshikazu Shibuya, Taketoshi Hasegawa and Yoshio Inuishi, “Estimation of Size of Vois in Coil Insulation of Rotating machinesâ€, IEEE Transactions on Electrical Insulation, Vol.EI-9, No.4, pp. 129-136, Dec.1974.
K.G. Burnley and J.L.T. Exon, “Relationship between various measurement techniques for void dischargesâ€, IEE Proceedings, Vol. 129, Pt. A, No. 8, pp. 593-606, Nov. 1982.
Sahoo Sahoo, N.C., Salama, M.M.A., R. Bartnikas, “Trends in partial discharge pattern classification: a surveyâ€, IEEE Transactions on Dielectric and Electrical Insulation, Vol. 12, Issue. 2, pp. 248–264, 2005.
M. Nafar, T. Niknam, A. Gheisari, “Using correlation coefficients for locating partial discharge in power transformerâ€, International Journal of Electrical Power & Energy Systems, Vol. 33, Issue 3, pp. 493-499, 2011.
A.Contin, E. Gulski, M. Cacciari, G.C. Montanari, “Applications of the Weibull Function to Partial Discharge Data coming from Different sources Typologiesâ€, Electrical Insulation and Dielectric Phenomena, pp. 335-338, 1995.
M. Cacciari, A. Contin, G. Rabach, G.C. Montanari, “Diagnosis of Practical Insulation Systems by Partial Discharge Measurements in the Presence of Multi-discharge Phenomenaâ€, International Conference on Electrical Insulation and Dielectric Phenomena, Pennsylvania, USA, pp. 414-419, 1993.
B. Freisleben, M. Hoof, R. Patsch, “Using Counter propagation Neural Networks for Partial Discharge Diagnosisâ€, International Journal of Neural Computing and Applications, Vol. 7, Issue 4, pp. 318-333, 1998.
R. Candela, G. Mirelli, R. Schifani, “Partial Discharge Recognition by Means of Statistical and Fractal Parameters and a Neural Networkâ€, IEEE Transactions on Dielectric and Electrical Insulation, 2000, Vol. 7, Issue 1, pp. 87-94, 2000.
A.Contin, A. Cavallini, G.C. Montanari, C. Hudon, M. Belec, N. Nguyen, “Searching for Indexes Suitable for Rotating Machines Diagnosisâ€, IEEE Intational Symposium on Electrical Insulation, pp. 101-105, 2006.
M. Mansor, P.S. Ghosh, A.B. Abdul Ghani, “PD Patterns Recognition in XLPE Cable Under Various Thermal Conditions Using Statistical Techniqueâ€, International Journal Research and Reviews in Applied Sciences, Vol. 5, Issue 2, pp. 171-181, 2010.
S. Biswas, D. Dey, B. Chatterjee, S. Chakravorti, “An approach based on rough set theory for identification of single and multiple partial discharge sourceâ€, International Journal of Electrical Power & Energy Systems, Vol. 46, pp. 163-174, 2013.
A.S. Deshpande, H.A. Mangalvedekar, A.N. Cheeran, “Partial Discharge Analysis using Energy Patternsâ€, International Journal Electrical Power Energy Systems, Vol. 53(C), pp. 184-95, 2013.
M. Noel, P. Basappa, V. Lakdawala, V. Nimbole, “A Neural Network Based System for Prediction of Partial Discharge Pulse Height Distribution Parametersâ€, IEEE International Symposium on Electrical Insulation, pp. 331-335, 2008.
C. Hudon, M. Belec, “PD Signal Interpretation for Generator Diagnosticsâ€, IEEE Transactions on Dielectric and Electrical Insulation, Vol. 12, Issue. 2, pp. 297-319, 2005.
M. Boltze, S. Markalous, A. Bolliger, “Insulation Condition Assessment of Generators Based on On-line and Off-line Monitoringâ€, 8th IndiaDoble Power Forum, Ahemdabad, India, 2010.
G.C. Stone, T. Goodeve, H. Sedding, W. McDermid, “Unusual PD Pulse Phase Distributions in Operating Rotating Machinesâ€, IEEE Transactions on Dielectric and Electrical Insulation, Vol. 2, Issue. 4, pp. 567-577, 1995.
B. Florkowska, Romuald Wlodek, “Pulse Height Analysis of Partial Discharges in Airâ€, IEEE Transactions on Dielectric and Electrical Insulation, Vol. 28, Issue. 6, pp. 932-940, 1993.
Jonathan dos Santos Cruz, Fabiano Fruett, Renato da Rocha Lopes, Fabio Luiz Takaki, Claudia de Andrade Tambascia, Eduardo Rodrigues de Lima & Mateus Giesbrecht, “Partial Discharges monitoring for Electric Machinery: A Reviewâ€, Energies, MDPI, vol. 15(21), pp. 1-31, October 2022.
Torstein Aakre , Emre Kantar , Espen Eberg . Partial Discharge Activity in Rotating Machine Type II Insulation Systems as a Function of Temperature and Frequency, IEEE Transactions on Dielectrics and Electrical Insulation, TechRxiv, pp.1-8, January, 2023.
Marek Florkowski, “Measurement of Partial Discharge Echo and Extraction of Decay Attributesâ€, Measurement, Vol. 238, pp.1-9, 2024.
Hassan, W., Hussain, G.A., Wahid, A., Safdar M., Khalid H.M and Mohd Jamil M K, “Optimum feature selection for classification of PD signals produced by multiple insulation defects in electric motorsâ€, Scientific Reports, nature portfolio, Vol.14:23446, pp. 1-17, 2024.
Andreas Rauscher, Johannes Kaiser, Manoj Devaraju, Christian Endisch, “Deep learning and data augmentation for partial discharge detection in electrical machinesâ€, Engineering Applications of Artificial Intelligence, Vol.133, 108074, Part A, pp. 1-17, 2024.
Abubakar, A.; Zachariades, C., “Phase-Resolved Partial Discharge (PRPD) Pattern Recognition Using Image Processing Template Matchingâ€, Sensors, Vol. 24, 3565., pp. 1-15, 2024.
A.Contin, G.C. Montanari, C. Ferraro, “PD source recognition by Weibull processing of Pulse Height Distributionsâ€, IEEE Transactions on Dielectric and Electrical Insulation, Vol. 7, Issue. 1, pp. 48-58, 2000.
R. Bartnikas, “Use of a Multichannel Analyzer for Corona Pulse-Height. Distribution Measurements on Cables and Other Electrical Apparatusâ€, IEEE Transaction on Instrumentation and Measurement, Vol. 22, Issue. 4, pp. 403-407, 1973.
M. Cacciari, A. Contin, G. Rabach, G.C. Montanari, “Use of Mixed-Weibull Distributions for the Identification of Partial Discharges Phenomenaâ€, IEEE Transactions on Dielectric and Electrical Insulation, Vol. 2, Issue. 4, pp. 614-627, 1995.
L.M. Rux, S. Grzybowski, “Detecting Delaminated Stator Winding Insulation Using the Ramped High Voltage DC Test Methodâ€, High Voltage Engineering Symposium, pp. 331-334, 1995.
B. Fruth, D. Gross, “Modelling of Streamer Discharges between Insulating and Conducting Surfacesâ€, IEEE 5th International Conference on Conduction and Breakdown in Solid Dielectrics, England, pp. 350-355, 1995.
B.M Reddy, “Insulation Condition Assessment Techniques on Rotating Machines with a Case Studyâ€, 8th IndiaDoble Power Forum, Ahemdabad, India, 2010.
B. Fruth and L. Niemeyer, “The Importance of Statistics Characteristics of Partial Discharge Dataâ€, IEEE Transactions on Electrical Insulation, Vol. 27, No. 1, pp. 60-69, Feb. 1992.
T. Ijichi, “A study on the ageing mechanisms of insulating materials by observing Ø – q – n pattern and current form of PDâ€, Master Thesis, Nagoya University 2001.
K. Wu, F. Komori, Y. Suzuoki, “Effects of oxygen on the formation of Rabbit-like PD pattern in a void between metal surfacesâ€, International Symposium on Electrical Insulating Materials, pp. 37-40, 2001.
Suwarno, Suzuoki Y., T. Mizutani, “Pulse Sequence Analysis of Partial Discharges in a void and Electrical Treeingâ€, IEEE Symposium on Electrical Insulation, Montreal, USA, 1996.